Vibration dampener solutions from compact to maxi
Whether pulling sheet piles, performing special foundation engineering work in urban areas, or handling sensitive suspended loads – the protection of people, machines, and the construction site is our top priority.
Our vibration and oscillation dampeners offer the right solution for every requirement – now also available for tensile forces up to 1200 kN!

Now new among the vibration and oscillation dampers: a real Maxi, the V S D 1200, for pull force requirements up to 120t.
Whether compact or powerful:
With our vibration dampers for special foundation engineering, you can protect your cranes and optimize construction processes.
We would be happy to help you find the right damper for your application – request a free, no-obligation quote now!

The V S D 30 – the popular all-rounder among vibration and oscillation dampers. Available for every application up to 16 t pull force.
One of our 250kN dampers was successfully used in a sheet pile wall removal operation in an inner-city area with a 250-ton mobile crane – in a very confined space, with a significant reduction in the crane load.

Vibration dampener for vibratory hammers against dangerous vibrations - advantages of mobile cranes pile pulling in inner-city areas.
Proven effectiveness: Vibration dampers reduce crane vibrations by up to 93%
In an independent performance study conducted by acoustics, noise and vibration experts VMS Australia, the VSD 70 and VSD 130 vibration dampers were tested under real-world construction site conditions – specifically during operations involving vibratory hammers and cranes.
Objective of the Study:
To measure the reduction in vibration transmission from the vibro hammer to the crane structure, with a focus on critical load scenarios such as sheet pile extraction.
Test Setup:
- Use of an 80-tonne crawler crane
- Two types of vibro hammers were tested:
• ICE 32NF (static moment)
• PVE 28VM (variable moment) - Vibration measurements were taken at the hook, boom, mid-boom, and inside the operator cabin
Key Findings:
- Up to 93% reduction in structural vibration levels with the SD130
- Up to 91% reduction with the SD70
- Particularly high dampening performance during pile extraction – the most critical load case
- Limited effect when the hammer is "sitting on the pile" (due to lack of active rope tension)
✅ Conclusion:
The study confirms: Our vibration dampers significantly reduce harmful vibrations, protect crane structures, and improve on-site safety – especially when extracting sheet piles using vibro hammers. In special foundation engineering, dampeners help protect equipment and workers – for safer, smoother operations.